FILMTEC Membranen  

  Produkte und Serviceleistungen

 

Produkt- und Spezifizierungrichtlinien 

 Tapewater - Elemente         
         TW - 2,5"
         TW - 4,0"
         TW - 4,6"

 Brackwasser - Elemente     
         BW - 2,5"
         BW - 4,0"
         BW - 8,0" 
        
XLE 440

  Meerwasser - Elemente     
         SW - 2,5"
         SW - 4,0"
         SW - 8,0"

Nanofiltrations - Elemente 
Full - Fit und andere Elemente 

Auslegungsrichtlinien 

Obligatorische Betriebsbedingungen 

Konservierung, Handhabung, Lagerung, Versand + Entsorgung 

Inbetriebsetzung von RO- Membransystemen 

Algemeine Reinigungsanleitung 

 

 

DESIGN GUIDELINES FOR FILMTEC ELEMENTS IN WATER TREATMENT

Feed Source  

RO Permeate  UF Permeate  Well Water Softened Supply Softened Surface Supply Surface Supply  Filtered Tertiary Effluent Seawater

Feed Silt Desnity Index

Max. Element Recovery % 40" (1m) Long Element

35 30 19 17 15 10 10

Max. Permeate Flow Rate Per Element, gpd (m³/d)

2.5" Diameter

Typical Membrane 
Active Area (ft²)

BW30-2540

24 800 (3.0) 700 (2.7) 600 (2.3) 500 (1.9) 500 (1.9) 300 (1.3) -

NF70-2540

23 - 700 (2.7) 600 (2.3) 500 (1.9) 500 (1.9) 300 (1.3) -

SW30/30HR-2540

23 - 700 (2.7) 600 (2.3) 500 (1.9) 500 (1.9) 300 (1.3) 500 (1.9)

4" Diameter

BW30-4040

82 2870 (11) 2570 (9.7) 2110 (8.0) 1870 (7.1) 1755 (6.-6) 1170 (4.4) -

BW30HP/LE-4040

82 2870 (11) 2570 (9.7) 2110 (8.0) 1870 (7.1) 1755 (6.6) 1170 (4.4) -

NF70-4040

82 - 2570 (9.7) 2110 (8.0) 1870 (7.1) 1755 (6.6) 1170 (4.4) -

SW30/30HR-4040

68 - 2200 (8.3) 1800 (6.8) 1600 (6.1) 1500 (5.6) 1000 (3.8) 1500 (5.6)

8" Diameter

BW30-330

330 10600 (40) 9000 (33) 7500 (28) 6500 (25) 5900 (22) 4000 (15) -

BW30-365

365 11700 (44) 9950 (38) 8300 (31) 7190 (27) 6520 (25) 4420 (17) -

BW30-400

400 12800 (48) 10970 (42) 9140 (24) 7920 (30) 7190 (27) 4870 (19) -

BW30LE-440

440 14100 (53) 12100 (46) 10000 (38) 8700 (33) 7900 (30) 5300 (20) -

NF70/90-400

400 12800 (48) 10970 (42) 9140 (24) 7920 (30) 7190 (27) 4870 (19) -

SG30LE-430

430 13800 (52) 11800 (45) 9800 (37) - - - -

SW30HR-380

380 - - - - 6874 (26) 4600 (17) 6900 (26)

At permeate flow rates lower than shown in the column for Filtered Tertiary ffluent, maximum element recovery is 20% for surface water and 15% for seawater. 
Note: The limiting values listed above have been incorportated into the ROSA (Reverse Osmosis System Analysis) software. 
Design of systems in excess of the guidelines results in a warning message on the ROSA printout. 

Max. Feed Flow Rate Per Element, US gpm (m³/h)

2.5" Diameter

6 (1.3) 6 (1.3) 6 (1.3) 6 (1.3) 6 (1.3) 6 (1.3) 6 (1.3)

4" Diameter

18 (4.1) 18 (4.1) 18 (4.1) 18 (4.1) 18 (4.1) 18 (4.1) 18 (4.1)

BW30-330

70 (16) 70 (16) 62 (14) 60 (14) 55 (12) 50 (11) -

BW30-365

73 (17) 73 (17) 65 (14) 63 (14) 58 (13) 52 (12) -

BW30/NF70/NF90-400

85 (19) 85 (19) 75 (17) 73 (17) 67 (15) 61 (14) -

SG30LE-430, BW30LE-440

85 (19) 85 (19) 75 (17) 73 (17) 67 (15) 61 (14) -

SW30HR-380 

- - - - - - 60 (14)

             

Min. Concentrate Flow Rate Per Element², U.S. gpm (m³/h

2.5" Diameter

0.5 (0.1) 0.5 (0.1) 1 (0.2) 1 (0.2) 1 (0.2) 1 (0.2) 1 (0.2)

4" Diameter

2 (0.5) 2 (0.5) 4 (0.9) 4 (0.9) 4 (0.9) 4 (0.9) 4 (0.9)

BW30-330

6 (1.4) 8 (1.8) 16 (3.6) 16 (3.6) 16 (3.6) 16 (3.6) 16 (3.6)

BW30-365

7 (1.6) 9 (1.9) 17 (3.9) 17 (3.9) 17 (3.9) 17 (3.9) 17 (3.9)

BW30/NF70/NF90-400

8 (1.8) 10 (2.2) 19 (4.4) 19 (4.4) 19 (4.4) 19 (4.4) 19 (4.4)

SG30LE-430, BW30LE-440

8 (1.8) 10 (2.2) 19 (4.4) 19 (4.4) 19 (4.4) 19 (4.4) 19 (4.4)

SW30HR-380 

             

We recommend that minimum concentrate flow rates be increased at the discretionof the designer by 20% for feed waters known to be high in fouling tendency (SDI>3).