DESIGN GUIDELINES FOR FILMTEC ELEMENTS IN WATER TREATMENT
|
Feed Source |
RO Permeate | UF Permeate | Well Water Softened Supply | Softened Surface Supply | Surface Supply | Filtered Tertiary Effluent | Seawater | |
|
Feed Silt Desnity Index |
||||||||
|
Max. Element Recovery % 40" (1m) Long Element |
35 | 30 | 19 | 17 | 15 | 10 | 10 | |
|
Max. Permeate Flow Rate Per Element, gpd (m³/d) |
||||||||
|
2.5" Diameter |
Typical
Membrane Active Area (ft²) |
|||||||
|
BW30-2540 |
24 | 800 (3.0) | 700 (2.7) | 600 (2.3) | 500 (1.9) | 500 (1.9) | 300 (1.3) | - |
|
NF70-2540 |
23 | - | 700 (2.7) | 600 (2.3) | 500 (1.9) | 500 (1.9) | 300 (1.3) | - |
|
SW30/30HR-2540 |
23 | - | 700 (2.7) | 600 (2.3) | 500 (1.9) | 500 (1.9) | 300 (1.3) | 500 (1.9) |
|
4" Diameter |
||||||||
|
BW30-4040 |
82 | 2870 (11) | 2570 (9.7) | 2110 (8.0) | 1870 (7.1) | 1755 (6.-6) | 1170 (4.4) | - |
|
BW30HP/LE-4040 |
82 | 2870 (11) | 2570 (9.7) | 2110 (8.0) | 1870 (7.1) | 1755 (6.6) | 1170 (4.4) | - |
|
NF70-4040 |
82 | - | 2570 (9.7) | 2110 (8.0) | 1870 (7.1) | 1755 (6.6) | 1170 (4.4) | - |
|
SW30/30HR-4040 |
68 | - | 2200 (8.3) | 1800 (6.8) | 1600 (6.1) | 1500 (5.6) | 1000 (3.8) | 1500 (5.6) |
|
8" Diameter |
||||||||
|
BW30-330 |
330 | 10600 (40) | 9000 (33) | 7500 (28) | 6500 (25) | 5900 (22) | 4000 (15) | - |
|
BW30-365 |
365 | 11700 (44) | 9950 (38) | 8300 (31) | 7190 (27) | 6520 (25) | 4420 (17) | - |
|
BW30-400 |
400 | 12800 (48) | 10970 (42) | 9140 (24) | 7920 (30) | 7190 (27) | 4870 (19) | - |
|
BW30LE-440 |
440 | 14100 (53) | 12100 (46) | 10000 (38) | 8700 (33) | 7900 (30) | 5300 (20) | - |
|
NF70/90-400 |
400 | 12800 (48) | 10970 (42) | 9140 (24) | 7920 (30) | 7190 (27) | 4870 (19) | - |
|
SG30LE-430 |
430 | 13800 (52) | 11800 (45) | 9800 (37) | - | - | - | - |
|
SW30HR-380 |
380 | - | - | - | - | 6874 (26) | 4600 (17) | 6900 (26) |
At permeate flow rates lower than shown in the column for Filtered Tertiary ffluent, maximum element recovery is 20%
for surface water and 15% for seawater.
Note: The limiting values listed above have been incorportated into the ROSA (Reverse Osmosis System Analysis)
software.
Design of systems in excess of the guidelines results in a warning message on the ROSA printout.
|
Max. Feed Flow Rate Per Element, US gpm (m³/h) |
|||||||
|
2.5" Diameter |
6 (1.3) | 6 (1.3) | 6 (1.3) | 6 (1.3) | 6 (1.3) | 6 (1.3) | 6 (1.3) |
|
4" Diameter |
18 (4.1) | 18 (4.1) | 18 (4.1) | 18 (4.1) | 18 (4.1) | 18 (4.1) | 18 (4.1) |
|
BW30-330 |
70 (16) | 70 (16) | 62 (14) | 60 (14) | 55 (12) | 50 (11) | - |
|
BW30-365 |
73 (17) | 73 (17) | 65 (14) | 63 (14) | 58 (13) | 52 (12) | - |
|
BW30/NF70/NF90-400 |
85 (19) | 85 (19) | 75 (17) | 73 (17) | 67 (15) | 61 (14) | - |
|
SG30LE-430, BW30LE-440 |
85 (19) | 85 (19) | 75 (17) | 73 (17) | 67 (15) | 61 (14) | - |
|
SW30HR-380 |
- | - | - | - | - | - | 60 (14) |
|
Min. Concentrate Flow Rate Per Element², U.S. gpm (m³/h |
|||||||
|
2.5" Diameter |
0.5 (0.1) | 0.5 (0.1) | 1 (0.2) | 1 (0.2) | 1 (0.2) | 1 (0.2) | 1 (0.2) |
|
4" Diameter |
2 (0.5) | 2 (0.5) | 4 (0.9) | 4 (0.9) | 4 (0.9) | 4 (0.9) | 4 (0.9) |
|
BW30-330 |
6 (1.4) | 8 (1.8) | 16 (3.6) | 16 (3.6) | 16 (3.6) | 16 (3.6) | 16 (3.6) |
|
BW30-365 |
7 (1.6) | 9 (1.9) | 17 (3.9) | 17 (3.9) | 17 (3.9) | 17 (3.9) | 17 (3.9) |
|
BW30/NF70/NF90-400 |
8 (1.8) | 10 (2.2) | 19 (4.4) | 19 (4.4) | 19 (4.4) | 19 (4.4) | 19 (4.4) |
|
SG30LE-430, BW30LE-440 |
8 (1.8) | 10 (2.2) | 19 (4.4) | 19 (4.4) | 19 (4.4) | 19 (4.4) | 19 (4.4) |
|
SW30HR-380 |
|||||||
We recommend that minimum concentrate flow rates be increased at the discretionof the designer by 20% for feed
waters known to be high in fouling tendency (SDI>3).
FILMTEC Membranen · FilmTec Corporation ist eine Tochtergesellschaft der The Dow Chemical Company